Private Canadian Company
Custom hydraulics
Drop-in replacement
API 610 pump upgrade
API 610 pump repair
Custom Casing
High temperature design
Rigid coupling patented
Robust std drip rim or drip pan base
High pressure design
Model HR / HOR
(OH2)
-
End suction & Top discharge
-
Option Top succion
-
Flow 15,000usgpm (3,400 m³ / h).
-
TDH 1,200 ft (365 m).
-
Temperature <800 ° F (425 ° C).
-
Design pressure std 725 psig (5,000 kPaG).
-
Higher pressure design available 1,450 psig (10,000 kPaG).
Model VP-B (OH3)
-
Side suction & side discharge
-
Grease lube bearings
-
Flexible coupling
-
Flow 8,000 US gpm (1,800 m³ / h).
-
TDH 1,200 ft (365 m).
-
Temperature <800 ° F (425 ° C).
-
Design pressure std 725 psig (5,000 kPaG).
-
Higher pressure design available 1,450 psig (10,000 kPaG).
Model VP-BOC (OH3)
-
Side suction & side discharge
-
Oil lube bearings
-
Flexible coupling
-
Flow 8,000 US gpm (1,800 m³ / h).
-
TDH 1,200 ft (365 m).
-
Temperature <800 ° F (425 ° C).
-
Design pressure std 725 psig (5,000 kPaG).
-
Higher pressure design available 1,450 psig (10,000 kPaG).
Model VP-CX (OH4)
-
Side suction & side discharge
-
No bearing housing
-
Trilink patented rigid coupling
-
Flow 8,000 US gpm (1,800 m³ / h).
-
TDH 1,200 ft (365 m).
-
Temperature <800 ° F (425 ° C).
-
Design pressure std 725 psig (5,000 kPaG).
-
Higher pressure design available 1,450 psig (10,000 kPaG).
Model VP-M
(OH5)
-
Side suction & side discharge
-
No bearing housing
-
Close coupled
-
Flow 8,000 US gpm (1,800 m³ / h).
-
TDH 1,200 ft (365 m).
-
Temperature <300 ° F (150 ° C).
-
Design pressure std 725 psig (5,000 kPaG).
Model HDR
(BB2)
-
1 stage, single or double suction
-
Top Suction & Top discharge
-
Option Same side nozzles
-
Option opposite side nozzles
-
Flow 25,000 US gpm (5,700 m³ / h).
-
TDH 1,400 ft (425 m).
-
Temperature <800 ° F (425 ° C).
-
Design pressure std 725 psig (5,000 kPaG).
-
Highest pressure design available
Model H2R (BB2)
-
2 stages, single / double suction
-
Top suction & Top discharge
-
Option Same side nozzles
-
Option opposite side nozzles
-
Flow 6,200 US gpm (1,400 m³ / h).
-
TDH 2,800 ft (850 m).
-
Temperature <800 ° F (425 ° C).
-
Design pressure std 725 psig (5,000 kPaG).
-
Highest pressure design available
Model HM (BB3)
-
Multi stages
-
Single or double suction
-
Opposite side nozzles
-
Flow < 4,400usgpm (1,000 m³ / h).
-
TDH < 5,600 ft (1,700 m).
-
Temperature < 400 ° F (200 ° C).
-
Design pressure std 2,250 psig (15,000 kPaG).
Nous sommes toujours là pour vous.
CONTACT US
1833 rue Langevin, Chambly, Québec, J3L 2E6
ppouliot@bep.services | Tel: +1 (514)889-6896